The EM console also displays the following error while trying to access the OID instance under Farm_IDMDomain -> Identity and Access -> oid1 or while trying to create a wallet for SSL
Error:
Information Configuration settings are unavailable because /Farm_IDMDomain/OID_Inst/oid1 is down.
There could be 2 reasons for this.
Reason1:
The WebLogic user password used by EM Console to monitor OID is not correct.
Solution:
- Go to the Farm drop down menu on the top of EM Console -> Agent Monitored Targets -> Configure . Verify if the Weblogic Monitoring User Name is correct and Change the WebLogic Monitoring Password to the correct password. Click Ok.
- Check the OID status now.
Reason2:
The IP address/hostname given in the Middleware Administration Server Service URL is wrong.
The following is an example of the Middleware Administration Server Service URL
service:jmx:t3://your_ip_address:7002/jndi/weblogic.management.mbeanservers.domainruntime
Solution:
- Go to the Farm drop down menu on the top of EM Console -> Agent Monitored Targets -> Configure .
- Try using hostname instead of IP address. Click OK and verify the status of OID from EM console.
No comments:
Post a Comment